Measurement of a PAGAT gel dosimeter by ultrasound computed tomography
نویسندگان
چکیده
منابع مشابه
Measurement of a PAGAT gel dosimeter via ultrasound CT
In this work we use a 3D quantitative CT imaging ultrasound system to characterise polymer gel dosimeters. The system comprises of two identical 5 MHz 128 element phasedarray ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound...
متن کاملFabrication and Optimization of a PAGATA Gel Dosimeter: Increasing the Melting Point of the PAGAT Gel Dosimeter with Agarose Additive
Introduction: The PAGAT polymer gel dosimeter melts at 30 ˚C and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. To increase the stability of the PAGAT gel, different amounts of agarose were added to the PAGAT gel composition and the PAGATA gel was manufactured. Material and Methods: The PAGATA gel vials were irradiated using a Co-60 ma...
متن کاملDetermination of Percentage Depth Dose (Pdd) of Pagat Gel Dosimeter By Electron Beams
Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...
متن کاملVerification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging
Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...
متن کاملOrgan Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms
Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography ...