Matrix-Driven Electron Source for MDS Flat-Panel CRT
نویسندگان
چکیده
منابع مشابه
A Low Emittance, Flat-beam Electron Source for Linear Colliders
We present a method to generate a flat (large horizontal to vertical emittance ratio) electron beam suitable for Linear Colliders. The concept is based on a round-beam rf-laser gun with finite solenoid field at the cathode together with a special beam optics adapter. Computer simulations of this new type of beam source show that the beam quality required for a Linear Collider may be obtainable ...
متن کاملAmorphous Silicon Flat Panel Imagers for Medical Application
A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...
متن کاملMDS-Tree and MDS-Matrix for High Dimensional Data Visualization
In this work, we propose MDS-Tree and MDS-Matrix as novel high dimensional data visualization methods to gain insight in both the data aspect and dimension aspect of the data. Dimension metrics of the high dimensional dataset are first computed to create a hierarchy. In an MDS-Tree, each node is an MDS projection of the original data items on a specific subset of dimensions associated with the ...
متن کاملA-Si FLAT PANEL
Flat Panel Illustration In 2000, a large array A-Si flat panel EPID detector was installed (AL-7) on one of the PRIMUS accelerator at UCSF to allow for a comparison of performance. During the development period of MVCBCT, the introduction in 2004 of a new flat panel (AG-9) better optimized for high energy photons showed a several fold increase in sensitivity, allowing the routine acquisition of...
متن کاملAn Active Matrix Flat Panel Dosimeter (AMFPD) for in-phantom dosimetric measurements.
An a-Si Active Matrix Flat Panel Imager (AMFPI) prototype developed in-house has been modified to function as an in-phantom dosimetry system providing high resolution two-dimensional (2-D) data. This Active Matrix Flat Panel Dosimeter (AMFPD) system can be used as a replacement device for standard in-phantom dosimeters, such as scanning ion chambers in water, or film in solid water. The initial...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Institute of Television Engineers of Japan
سال: 1990
ISSN: 0386-6831,1884-9652
DOI: 10.3169/itej1978.44.1588