Massive osteolysis due to galvanic corrosion after total knee arthroplasty: a rare cause for early revision?
نویسندگان
چکیده
منابع مشابه
Revision Total Knee Arthroplasty due to Rheumatoid Arthritis after Unicompartmental Knee Arthroplasty: A Case Report
Objective: We report a rare case of revision total knee arthroplasty (TKA) for monoarthritis of the knee due to rheumatoid arthritis (RA). The patient underwent revision surgery at 8 years and 7 months after left unicompartmental knee arthroplasty (UKA). Case: The patient was a 72-year-old woman. She subsequently presented to the previous hospital with left knee pain of spontaneous onset at 7 y...
متن کاملRevision total knee arthroplasty for unexplained pain after unicompartmental knee arthroplasty: a case report.
In this report, we present a case of a 64-year-old woman who underwent revision of knee arthroplasty after failed unicompartmental knee arthroplasty (UKA). She underwent UKA (Biomet Oxford Phase 3) for right localized medial knee pain at the age of 53 and the postoperative course had been uneventful. Eight years after UKA, she had right knee pain that gradually worsened. Tenderness was present ...
متن کاملAlternatives to revision total knee arthroplasty.
Most problems encountered in complex revision total knee arthroplasty can be managed with the wide range of implant systems currently available. Modular metaphyseal sleeves, metallic augments and cones provide stability even with significant bone loss. Hinged designs substitute for significant ligamentous deficiencies. Catastrophic failure that precludes successful reconstruction can ...
متن کاملRevision of Total Knee Arthroplasty
75 experience of the leading authorities in Cardiothoracic transplantation medicine and in this second edition he consolidates this. It comprises four sections, eighty chapters and some eight hundred and twenty four pages. This is a comprehensive and readable review of the "state of the art" in the field of Cardiothoracic transplantation and replacement of thoracic organs. The contributors are ...
متن کاملRotating-hinge total knee for revision total knee arthroplasty.
Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Surgical Case Reports
سال: 2020
ISSN: 2042-8812
DOI: 10.1093/jscr/rjaa002