MASSIF1: fully automated macromolecular crystallography
نویسندگان
چکیده
منابع مشابه
AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery.
AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on scree...
متن کاملMacromolecular Crystallography at Chess
CHESS activity report F many years, most synchrotron stations for crystallography, such as CHESS A1, used X-ray sensitive film as the primary detector and xray radiation at about 8 keV (1.5 Å). Two years ago CHESS constructed station F1 on a wiggler line that is tuneable from about 7-14 keV. In practice, this station operates with a standard energy of 0.91 Å. The benefits of using higher energi...
متن کاملStrategies for macromolecular synchrotron crystallography.
Introduction During the past ten years the rate of protein structure determination by X-ray crystallography has risen about tenfold [1]. The use of synchrotron radiation was instrumental for this growth and the fraction of the results obtained this way increased from 28% in 1990 to 80% in 1999 (Figure 1). There are 52 synchrotron stations worldwide used for macromolecular crystallography, and t...
متن کاملData Processing in Macromolecular Crystallography
Data processing in macromolecular crystallography is the effort by which a user converts a set of raw diffraction data into a list of Bragg reflections with measured intensities. With modern crystallographic hardware the raw data consists of a set of twodimensional detector images, each collected at a particular orientation of the crystal. Data processing may be broken down into four steps: cal...
متن کاملMacromolecular crystallography beamline X25 at the NSLS
Beamline X25 at the NSLS is one of the five beamlines dedicated to macromolecular crystallography operated by the Brookhaven National Laboratory Macromolecular Crystallography Research Resource group. This mini-gap insertion-device beamline has seen constant upgrades for the last seven years in order to achieve mini-beam capability down to 20 µm × 20 µm. All major components beginning with the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica Section A Foundations and Advances
سال: 2015
ISSN: 2053-2733
DOI: 10.1107/s2053273315095947