منابع مشابه
Gas diffusion electrodes improve hydrogen gas mass transfer for a hydrogen oxidizing bioanode
Background Bioelectrochemical systems (BESs) are capable of recovery of metals at a cathode through oxidation of organic substrate at an anode. Recently, also hydrogen gas was used as an electron donor for recovery of copper in BESs. Oxidation of hydrogen gas produced a current density of 0.8 A m-2 and combined with Cu2+ reduction at the cathode, produced 0.25 W m-2. The main factor limiting cu...
متن کاملLocal visualization of catalytic activity at gas evolving electrodes using frequency-dependent scanning electrochemical microscopy.
A new concept for the localized characterization of gas evolving electrodes based on scanning electrochemical microscopy (SECM) is suggested. It offers information about the spatial distribution of the predominant locations, which represent the most active catalytic sites, and dynamic characteristics of gas-bubble departure. The knowledge about gas-bubble departure is critical for the assessmen...
متن کاملMeasurement of Mass Transfer Coefficients of Natural Gas Mixture during Gas Hydrate Formation
In this study, mass transfer coefficients (MTC’s) of natural gas components during hydrate formation are reported. This work is based on the assumption that the transport of gas molecules from gas phase to aqueous phase is dominant among other resistances. Several experiments were conducted on a mixture of natural gas at different pressures and temperatures and the consumed gas was monitored an...
متن کاملSingle nanoparticle collisions at microfluidic microband electrodes: the effect of electrode material and mass transfer.
We report on the effect of convection on electrochemically active collisions between individual Pt nanoparticles (PtNPs) and Hg and Au electrodes. Compared to standard electrochemical cells utilizing Hg and Au ultramicroelectrodes (UMEs) used in previous studies of electrocatalytic amplification, microelectrochemical devices offer two major advantages. First, the PtNP limit of detection (0.084 ...
متن کاملMass Transfer in a Closed Stirred Gas / Liquid Contactor Part 1 : The Mass Transfer Rate
Liquid phase mass transfer rates kLS for the absorption of oxygen in tap water and in aqueous ionic solutions have been determined in two closed stirred tank contactors for a power input between 3 and 70 W/kg and (impeller diameter)f(tank diameter) ratios DifT of 0.3, 0.35 and 0.4. The contactors had diameters of 0. I9 and 0.6 m. The dispersed phase fraction was 1% by volume in all experiments....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electrochimica Acta
سال: 1978
ISSN: 0013-4686
DOI: 10.1016/0013-4686(78)80101-7