Mass Spectrometry Goes With the Flow
نویسندگان
چکیده
منابع مشابه
Sodium Channel Inactivation Goes with the Flow
Voltage-dependent inactivation of Na ϩ channels is a consequence of voltage-dependent activation (Aldrich et al., 1983), and inactivation is characterized by at least two distinguishable kinetic components: an initial rapid component (fast inactivation) and a slower component (slow inactivation). Within milliseconds of opening, Na ϩ channels enter a nonconducting inacti-vated state as the inact...
متن کاملHow VE-cadherin goes with the flow
Vascular endothelial cells respond to changes in blood fl ow (1). Increased fl ow, for example, causes vasodilation and blood vessel remodeling. Collectively, these responses are critical for both vascular development and the maintenance of adult blood vessels. Moreover, disturbed blood fl ow patterns—at artery branch points, for instance—can activate infl ammatory pathways that may initiate th...
متن کاملNanoliter Segmented-Flow Sampling Mass Spectrometry with Online Compartmentalization
We report a microfluidic device, using segmented flow in a two-phase system of immiscible liquids, which delivers aqueous droplets into a modified commercial mass spectrometer. The interface coupling the microfluidics to the mass spectrometer achieves up to 96% sample transfer efficiency to the vacuum chamber. Sample ionization is assisted by multipass infrared laser beam in the interface. The ...
متن کاملContinuous-flow fast atom bombardment mass spectrometry.
The continuous-flow fast atom bombardment probe performs equally well with or without a high-performance liquid chromatography column producing clean spectra containing little or no background noise. Its function as a liquid chromatography-mass spectrometry interface for labile and involatile samples has been illustrated with reference to dansylated amino acids. The versatility of the new probe...
متن کاملTrace analysis of benzalkonium chloride on skin by flow injection ionspray mass spectrometry-mass spectrometry.
A method for the analysis of trace-level benzalkonium chloride has been established using flow injection ionspray mass spectrometry-mass spectrometry with multiple reaction monitoring. Quantification was carried out using an external standard based on peak area summation of each benzalkonium ion (C8, C10, C12, C14, C16 and C18) in the mass spectra. The multiple reaction monitoring technique pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Circulation: Cardiovascular Genetics
سال: 2012
ISSN: 1942-325X,1942-3268
DOI: 10.1161/circgenetics.112.963694