Mass Spectrometry Contamination from Tinuvin 770, a Common Additive in Laboratory Plastics
نویسندگان
چکیده
منابع مشابه
Comparative study on cardiotoxic effect of Tinuvin 770: a light stabilizer of medical plastics in rat model.
Tinuvin 770 [bis(2,2,6,6-tetramethyl-4-piperidinyl) sebacate], is a UV light stabilizer plastic additive used worldwide. It is a component of many plastic materials used in medical and food industries. Earlier studies demonstrated its in vitro L-type Ca2+ channel and nicotinic acetylcholine receptor blocking properties. Our previous experiments have proved the toxic effects of Tinuvin 770 on is...
متن کاملA light stabilizer (Tinuvin 770) that elutes from polypropylene plastic tubes is a potent L-type Ca(2+)-channel blocker.
A pharmacologically active agent was easily extracted by aqueous or organic solvents from laboratory plastic tubes (Falcon Blue Max) and has been chemically identified as bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate. This compound (approximately 12 micrograms per tube approximately 25 nmol) blocked 1,4-dihydropyridine-sensitive 45Ca2+ uptake into GH3 cells with an IC50 value of 3.6 microM, inh...
متن کاملEffective Use of Mass Spectrometry in the Clinical Laboratory.
BACKGROUND Historically the success of mass spectrometry in the clinical laboratory has focused on drugs of abuse confirmations, newborn screening, and steroid analysis. Clinical applications of mass spectrometry continue to expand, and mass spectrometry is now being used in almost all areas of laboratory medicine. CONTENT A brief background of the evolution of mass spectrometry in the clinic...
متن کاملLiquid chromatography-tandem mass spectrometry--application in the clinical laboratory.
This review provides a concise survey of liquid chromatography-tandem mass spectrometry (LC-TMS) as an emerging technology in clinical chemistry. The combination of two mass spectrometers with an interposed collision cell characterizes LC-TMS as an analytical technology on its own and not just as a more specific detector for HPLC compared with conventional techniques. In LC-TMS, liquid chromato...
متن کاملLiquid chromatography tandem mass spectrometry in the clinical laboratory.
Clinical laboratory medicine has seen the introduction and evolution of liquid chromatography tandem mass spectrometry in routine clinical laboratories over the last 10-15 years. There still exists a wide diversity of assays from very esoteric and highly specialist manual assays to more simplified kit-based assays. The technology is not static as manufacturers are continually making improvement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomolecular Techniques : JBT
سال: 2013
ISSN: 1524-0215,1943-4731