Mass and position determination of attached particles on cantilever based mass sensors.

An analytical expression relating mass and position of a particle attached on a cantilever to the resulting change in cantilever resonant frequency is derived. Theoretically, the position and mass of the attached particle can be deduced by combining measured resonant frequencies of several bending modes. This finding is verified experimentally using a microscale cantilever with and without an a...

متن کامل

Mass determination and sensitivity based on resonance frequency changes of the higher flexural modes of cantilever sensors.

Micro- and nanocantilevers are increasingly employed as mass sensors. Most studies consider the first flexural mode and adsorbed masses that are either discretely attached or homogeneously distributed along the entire length of the cantilever. We derive general expressions that allow for the determination of the total attached mass with any mass distribution along the cantilever length and all ...

متن کامل

Fabrication of cantilever based mass sensors integrated with CMOS using direct write laser lithography on resist

A CMOS compatible direct write laser lithography technique has been developed for cantilever fabrication on pre-fabricated standard CMOS. We have developed cantilever based sensors for mass measurements in vacuum and air. The cantilever is actuated into lateral vibration by electrostatic excitation and the resonant frequency is detected by capacitive readout. The device is integrated on standar...

متن کامل

Precise mass determination of single cell with cantilever-based microbiosensor system

Having determined the mass of a single cell of brewer yeast Saccharomyces cerevisiae by means of a microcantilever-based biosensor Cantisens CSR-801 (Concentris, Basel, Switzerland), it was found that its dry mass is 47,65 ± 1,05 pg. Found to be crucial in this mass determination was the cell position along the length of the cantilever. Moreover, calculations including cells positions on the ca...