Masking of short tone bursts of frequency sweeps
نویسندگان
چکیده
منابع مشابه
Normative behavioral thresholds for short tone-bursts.
Although tone-bursts have been commonly used in auditory brainstem response (ABR) evaluations for many years, national standards describing normal calibration values have not been established. This study was designed to gather normative threshold data to establish a physical reference for tone-burst stimuli that can be reproduced across clinics and laboratories. More specifically, we obtained n...
متن کاملMasking of tone bursts by modulated noise in normal, noise-masked normal, and hearing-impaired listeners.
Threshold of 4.6-ms tone bursts was measured in quiet and in the presence of a 100% sinusoidally amplitude-modulated speech-shaped noise. For the modulated-noise conditions, the onset of the tone burst coincided either with the maximum or the minimum modulator amplitude. The difference in these two masked thresholds provided an indication of the psychoacoustic modulation depth, or the modulatio...
متن کاملRise time and center-frequency effects on auditory brainstem responses to high-frequency tone bursts.
The effects of rise time and center frequency on the auditory brainstem response (ABR) elicited by high-frequency tone bursts were examined in six normal-hearing adults. Tone bursts with rise times of 0.1, 0.25, 0.5, and 1.0 msec, duration of 2 msec, and center frequencies of 8, 10, and 12 kHz were used in this study. The absolute latencies of waves I, III, and V were obtained in all subjects, ...
متن کاملTransient responses to tone bursts.
Investigating theoretical conditions under which linearly-operating tuned structures produce click-like transient responses to onsets and offsets of trapezoidal tone bursts, we come to the following conclusions: (1) each of the four corners of the trapezoidal tone burst is capable of eliciting such a response; (2) the amplitude of the response and its dependence on the frequency of the modulate...
متن کاملReliability of evoked responses to high-frequency (8-14 kHz) tone bursts.
Instrumentation to evaluate the auditory brainstem response to high-frequency (8-14 kHz) tone bursts has been developed in the Auditory Research Laboratory, Portland, Oregon VA Medical Center. This system is intended to monitor the audition of patients receiving ototoxic drugs who are unresponsive to behavioral test procedures. The reliability of responses obtained with the high-frequency tone-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Acoustical Society of America
سال: 1987
ISSN: 0001-4966
DOI: 10.1121/1.2025056