Marinobacter atlanticus electrode biofilms differentially regulate gene expression depending on electrode potential and lifestyle
نویسندگان
چکیده
منابع مشابه
Electrode Potential Induced Reorientation of a Phospholipid Monolayer on a Mercury Electrode Surface
Rapid scan cyclic voltammetry has been employed to probe the potential induced transitions of a dioleoylphosphatidylcholine (diOPC) monolayer deposited onto a mercury surface. By employing two different types of electrodes, a hanging mercury drop electrode (HMDE) and a mercury-film-coated gold electrode (J-electrode), we were able to deposit the diOPC monolayer in tails-down and heads-down fash...
متن کاملElectrode potential and selective ionic adsorption
Article history: Received 11 March 2009 Accepted 16 March 2009 Available online 20 March 2009 Communicated by V.M. Agranovich A simple description of the electrode potential based on the selective ionic adsorption is proposed. It is shown that if the adsorption–desorption coefficients entering in the Langmuir kinetic equation for the adsorption at the limiting surfaces are not identical, a diff...
متن کاملThe wall-jet electrode Potential step chronoamperometry
A theory is presented which describes the transient current response to a potential step at a wall-jet electrode, thus defining the “response time” of the electrode. Results are given in the form of a normalized transient as a function of a dimensionless time parameter which permits the analysis of experimental data for electrodes of any geometry and for any solution flow rate.
متن کاملEffect of Bubbling on the Potential of Reference Electrode
The method for the examination of gas/water interface electrokinetic behavior is developed. "Bubbling potential", i.e. the difference in the potential of the indicator electrode in the absence and presence of gas bubbles was measured. The indicator electrode is a reference electrode with the porous plug exposed to gas bubbles. The charged bubble in contact with the porous plug would affect the ...
متن کاملMultifocal visual evoked potential is dependent on electrode position.
PURPOSE To investigate whether the multifocal visual evoked potential (mVEP) is dependent on the electrode position, and to confirm the reproducibility of the mVEP. METHODS The mVEPs were recorded using the Veris III system with two different bipolar electrode settings. In Position 1, electrodes were placed at equal distances in vertical alignment 2 cm above and below the inion. In Position 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biofilm
سال: 2021
ISSN: 2590-2075
DOI: 10.1016/j.bioflm.2021.100051