Marine reservoir corrections and the calibration curve
نویسندگان
چکیده
منابع مشابه
Curve matching and stereo calibration
These lines are the intersections of the plane through the point p in the world and the centres of the left and right cameras with the two camera focal planes (see Figure 1). These epipolar lines are formed by the intersections of the pencil of planes through the line joining the image centres with the camera focal planes. Hence such lines form a pencil passing through the point of intersection...
متن کاملCalibration of Area-Reduction Empirical Method for Dam Reservoir
The mathematical model of Area-Reduction empirical method is written through MATLAB software. Three periods of the hydrologic survey are required to run, calibrate and validatethe model. The Dez Dam, which is one of the most significant dams of the Middle East with three periods of hydrographic surveys in 1972, 2002 and 2011, has been chosen for the investigation. The annual average of the inpu...
متن کاملconsequence analysis of the leakage, ignition and explosion during high pressure sour gas injection process to the oil reservoir
there is no doubt that human being needs to become integrated with industry and industry needs to be progressed, daily. on the other hand, serious events in industrial units specially in oil industries has been shown that such damages and events are industry related ones. the consequence of such events and damages which resulted in chemical and poisoned explosions and loss of life and property ...
Reservoir offset models for Radiocarbon calibration
The purpose of a reservoir offset is to enable the application of calibration data (μ(θ), e.g. Stuiver et al. 1998) developed for one reservoir (primary reservoir) to CRA’s from another (secondary reservoir). The usual approach has been to define the activity of the secondary reservoir as some form of constant offset (with error) from the primary reservoir (e.g. Stuiver and Braziunas 1993). In ...
متن کاملEMF [ mV ] t EMF [ mV ] t CALIBRATION CURVE FOR CATION I CATION INTERFERENCE CALIBRATION CURVE
Among the techniques of detection used in clinical chemistry, optical and electrochemical methods are especially attractive. However, except for glass electrodes for pH measurement, potentiometric electrochemical sensors (ionselective electrodes) gained general acceptance in clinical analyzers and in clinical instrumentation, respectively, only around 1970 (for reviews see 1-5). Here we report ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PAGES news
سال: 2006
ISSN: 1563-0803,1563-0803
DOI: 10.22498/pages.14.3.12