Management of closed tibial plateau fractures with percutaneous cancellous screw fixation
نویسندگان
چکیده
منابع مشابه
Closed reduction and percutaneous screw fixation for tibial plateau fractures.
PURPOSE To evaluate treatment outcomes of closed reduction and percutaneous screw fixation for tibial plateau fractures. METHODS 48 men and 8 women aged 19 to 61 (mean, 36) years underwent closed reduction and percutaneous screw fixation for closed tibial plateau fractures with <5 mm depression. According to the Schatzker classification, patients were classified into type I (n=9), type II (n=...
متن کاملFailure of fixation of tibial plateau fractures.
OBJECTIVE To define the failure of fixation in tibial plateau fractures, detect its incidence, and determine the contributing factors. DESIGN Mail survey and literature review were used to define the fixation failure; this definition was applied to a radiologic review of patients who were treated surgically for tibial plateau fracture at a Level 1 trauma unit for a three-year period from 1993...
متن کاملInterference screw technique for arthroscopic reduction and internal fixation of compression fractures of the tibial plateau.
Arthroscopic reduction and internal fixation (ARIF) is recommended as state-of-the-art treatment for patients with pure compression fracture of the tibial plateau. We describe a new technique for ARIF of pure compression tibial plateau fractures that uses a cannulated, bioabsorbable interference screw. After a guide pin is placed in the center of the compressed fragment and a tamp is used to el...
متن کاملPreliminary Result of Percutaneous Screw Fixation for Bone Bruise of the Tibial Plateau.
This study reports the preliminary results of surgical treatment of bone bruise of the tibial plateau. Twelve patients underwent percutaneous screw fixation with a mean follow-up of 15 months. The mean duration of surgery was 15 minutes. Preoperatively, 1 week postoperatively, 1 month postoperatively, 6 months postoperatively, and 12 months postoperatively, the mean visual analog scale scores w...
متن کاملThe effect of screw type on the fixation of depressed fragments in tibial plateau fractures.
The ability of various screw types to stabilize depressed tibial plateau fractures was determined in a biomechanical study using a Sawbones model. Two sizes of both cancellous and cortical screws were evaluated for both supportfrom below and through the depressed fragment. As a general trend, cancellous bone screws provided a greater resistance to fragment displacement than cortical bone screws...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Journal of Dr. D.Y. Patil University
سال: 2013
ISSN: 0975-2870
DOI: 10.4103/0975-2870.108639