Malfunctioning transducer cable causes underestimation of arterial blood pressure
نویسندگان
چکیده
منابع مشابه
Diagnosis of Different Causes of Arterial Blood Pressure by Arterial Catheter and Kidney Vein - A Case Report
1. Nous pouvons trouve une correlation precise entre les dosage de la renine et les aspects angiographiques uniquement dans les cas d'hypertension arterielle nephrovasculaire·. 2. Cette correlation est importante pour deci. <l_er d'une="" intervention="" chirurgicale="" surtout="" en="" cas="" de="" lesion="" monolaterales,qui="" datent="" peu="" temps="" et="" qui="" ont="" valeurs="" ren...
متن کاملCytomegalovirus Infection Causes an Increase of Arterial Blood Pressure
Cytomegalovirus (CMV) infection is a common infection in adults (seropositive 60-99% globally), and is associated with cardiovascular diseases, in line with risk factors such as hypertension and atherosclerosis. Several viral infections are linked to hypertension, including human herpes virus 8 (HHV-8) and HIV-1. The mechanisms of how viral infection contributes to hypertension or increased blo...
متن کاملInterpretation of Arterial Blood Gas
تجزیه و تحلیل گازهای خون اطلاعات مهمی را در مورد اکسیژناسیون شریانی و تعادل اسید - باز در دست ما قرار می دهد. در ک این داده ها بخشی اساسی از مراقبت پرستاری در اکثر بیماران است. هنوز برای بسیاری از پرستاران، تفسیر نتایج گازهای خون شریانی همانند یک جدول پیچیده بوده و در مواقعی که بررسی تمام نتایج در اسرع وقت مورد نیاز باشد، این مشکل بیشتر نمایان می شود.
متن کاملTHE EFFECT OF ARTERIAL O2 SATURATION AND HE ART RATE ON BLOOD PRESSURE DURING HYPOXIA
A periodic increase in blood pressure (BP) occurs during apneic episodes in patients with obstructive sleep apnea (OSA). Several factors including hypoxemia and an increase in heart rate (HR) were reported to be responsible for this increased BP. To examine the contribution of these two factors in increasing BP, 35 healthy male subjects (mean age±SD= 23.64±3.80) were studied in three experi...
متن کاملA new optical transducer for arterial pressure measurement.
A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2004
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.2004.03732.x