Maleic Anhydride Grafting on EPDM: Qualitative and Quantitative Determination
نویسندگان
چکیده
منابع مشابه
Grafting of Tetrahydrophthalic and Maleic Anhydride Onto Polyolefins in Solution
Polietileno de baixa densidade (LLDPE) com comonômeros 1-buteno e 1-octeno foram funcionalizados com anidrido tetrahidroftálico (THA) e anidrido maléico (MA) em solução na presença de peróxido de benzoíla (BPO), de acordo com planejamentos fatoriais. As variáveis testadas foram concentração de anidrido, concentração de peróxido, tempo de reação e tipo de comonômero. As formulações foram analisa...
متن کاملGrafting of Maleic Anhydride onto Co)propylene-b-ethylene( by Extrusion Process: Measurement of Adhesion to Steel Surface
Polypropylene (PP) has poor adhesion to metals and other surfaces for its chemical structure. Hence, chemical modification of PP is necessary for metal surface coating application. In this research, grafting of maleic anhydride (MA) onto co(propylene-b-ethylene) in the presence of a dicumyl peroxide (DCP) was accomplished in a single screw extruder. Characteristics of the modified polymer were ...
متن کاملFabrication and Characterization of Proton Conductive Membranes Based on Poly(methyl methacrylate-co-maleic anhydride)
In this study, proton conductive composite membranes were produced by using a poly(methylmethacrylate-co-maleic anhydride) (P(MMA-co-MAH)) copolymer and phosphotungstic Acid (PWA) as an additive of the proton conductive agent. P(MMA/MAH) 70/30, 50/50, and 30/70 were synthesized using a free radical polymerization reaction. PWA with a concentration of 2% was added to...
متن کاملGrafting of Maleic Anhydride onto Co)propylene-b-ethylene( by Extrusion Process: Measurement of Adhesion to Steel Surface
Polypropylene (PP) has poor adhesion to metals and other surfaces for its chemical structure. Hence, chemical modification of PP is necessary for metal surface coating application. In this research, grafting of maleic anhydride (MA) onto co(propylene-b-ethylene) in the presence of a dicumyl peroxide (DCP) was accomplished in a single screw extruder. Characteristics of the modified polymer were ...
متن کاملQualitative and Quantitative Approaches for Determination of Hemolyzed Serum
Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 1999
ISSN: 0103-5053
DOI: 10.1590/s0103-50531999000100006