Magnon laser based on Brillouin light scattering
نویسندگان
چکیده
منابع مشابه
Shear Brillouin light scattering microscope.
Brillouin spectroscopy has been used to characterize shear acoustic phonons in materials. However, conventional instruments had slow acquisition times over 10 min per 1 mW of input optical power, and they required two objective lenses to form a 90° scattering geometry necessary for polarization coupling by shear phonons. Here, we demonstrate a confocal Brillouin microscope capable of detecting ...
متن کاملThermal Effects Study on Stimulated Brillouin Light Scattering in Photonic Crystal Fiber
we investigate the temperature-dependences of the Brillouin frequency shift in three different kind of single-mode fibers using a heterodyne method for sensing temperature. Positive dependences coefficients of 0.77, 0.56 and 1.45MHz/0C are demonstrated for 25 km long single-mode fiber, 10 km long non-zero dispersion shifted fiber and 100 m photonic crystal fiber, respectively. The results indic...
متن کاملAnomalous stimulated Brillouin scattering via ultraslow light.
We study stimulated Brillouin scattering (SBS) in an ultradispersive coherent medium, and show that the properties of SBS change drastically when the group velocity of light in the material approaches or becomes less than the speed of sound. In particular, forward SBS not allowed in a dispersionless bulk medium takes place in the coherent medium.
متن کاملBrillouin light-scattering from polymer gels
The experimental results of the Brillouin shift and width for poly(vinyl alcohol) and poly(vinyl chloride) gels as a function of gel network volume fraction have been analysed using the theory of Marqusee and Deutch for Brillouin light-scattering from polymer gels, incorporated with a new plausible assumption relating the speed of sound in the gel network with its volume fraction. It has been f...
متن کاملLaser Light Scattering Detectors
On-line coupling of high performance liquid chromatography (HPLC) to capillary gas chromatography (GC) means that LC fractions comprising one or several peaks are directly transferred to the gas chromatograph, mostly in a fully automated mode. The Rrst coupled system, developed by R. Majors in 1980, involved splitless injection by means of a GC autosampler andmerely transferred a small part of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Letters
سال: 2020
ISSN: 0146-9592,1539-4794
DOI: 10.1364/ol.401689