Magnetoelectronic Spin Echo

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetoelectronic spin echo.

We predict a spin echo in electron transport through layered ferromagnetic-normal-ferromagnetic metal structures: whereas a spin current polarized perpendicular to the magnetization direction decays when traversing a single homogeneous ferromagnet on the scale of the ferromagnetic spin-coherence length, it partially reappears by adding a second identical but antiparallel ferromagnet. This reent...

متن کامل

Thermal spin-transfer torque in magnetoelectronic devices.

We predict that the magnetization direction of a ferromagnet can be reversed by the spin-transfer torque accompanying spin-polarized thermoelectric heat currents. We illustrate the concept by applying a finite-element theory of thermoelectric transport in disordered magnetoelectronic circuits and devices to metallic spin valves. When thermalization is not complete, a spin heat accumulation vect...

متن کامل

Fast Spin Echo Imaging

In conventional spin echo (SE) imaging, the longitudinal magnetization (that is generated by the presence of the main magnetic field, B0) is tipped into the transverse plane using a radiofrequency (RF) pulse that tips the magnetization 90 degrees. Once in the transverse plane, the magnetization rotates, or precesses, around the axis of the main magnetic field. As the transverse magnetization pr...

متن کامل

Simultaneous spin-echo refocusing.

A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminat...

متن کامل

Fast Spin- Echo

Imaging with T2-weighting is prescribed in nearly every diagnostic imaging protocol, owing to the fact that in many pathologic states, diseased tissue may be distinguished from normal tissue through apparent differences in T2. Conventional T2-weighted imaging carries with it a heavy time cost, however, as a relatively long time must be allowed between acquisitions in order to allow T1 recovery ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Letters

سال: 2003

ISSN: 0031-9007,1079-7114

DOI: 10.1103/physrevlett.91.166601