Magnetically responsive materials for solid phase extraction
نویسندگان
چکیده
منابع مشابه
Temperature-responsive Solid-phase Extraction Column for Biological Sample Pretreatment.
We have developed a novel solid-phase extraction (SPE) system utilizing a temperature-responsive polymer hydrogel-modified stationary phase. Aminopropyl silica beads (average diameter, 40 - 64 μm) were coated with poly(N-isopropylacrylamide) (PNIPAAm)-based thermo-responsive hydrogels. Butyl methacrylate (BMA) and N,N-dimethylaminopropyl acrylamide (DMAPAAm) were used as the hydrophobic and cat...
متن کاملRecent Development and Application of Solid Phase Extraction Materials
Recently, the solid phase extraction technology has received considerable attention considering serious environmental problems and much more contaminants present in the samples at trace level that is different to be analyzed. During the whole process of analyzing sample, the preconcentration of sample is the most complicated and significant step, which typically spend much time, affecting the a...
متن کاملMagnetically responsive pickering foams.
We introduce a new class of Pickering foams which can be manipulated using a magnetic field. These foams are stabilized by a mixture of magnetic and nonmagnetic particles. They exhibit excellent stability in the absence of a magnetic field, but can be rapidly destroyed on demand with the application of a threshold field. We characterize their stability in the absence of a magnetic field by meas...
متن کاملPermittivity and Permeability Extraction of Magnetically Loaded Absorbing Materials
New procedure for permittivity and permeability extraction of two composite (dielectric matrix + magnetic inclusions), isotropic and homogeneous absorbing material is presented. It calculates mentioned parameters by fitting measured transmission data with Debye relaxation model (for complex dielectric permittivity extraction) and with Lorenzian resonant model (for complex permeability extractio...
متن کاملMicroscale solid-phase extraction system for explosives.
A simple, semi-automated, microcolumn solid-phase extraction (SPE) system is optimized for the extraction, preconcentration and HPLC analysis of seven different explosives and explosive derivatives contaminating seawater, river water and well water samples. The microcolumns were constructed from 1/16 in. O.D. PTFE tubing (1 in.=2.54 cm) packed with 0.5-1.5 mg of SPE material. LiChrolut EN or Po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Environmental engineering
سال: 2019
ISSN: 1849-5079,1849-4714
DOI: 10.37023/ee.6.1.3