MAGNETIC SYSTEM FOR CLEANING THE GAMMA BEAM AT THE LUE-40 ELECTRON LINAC OUTPUT
نویسندگان
چکیده
The bremsstrahlung of accelerated electrons passing through a converter is used to study multiparticle photonuclear reactions. results calculations, numerical modeling, design, and testing special magnetic cleaning system obtain “pure” beam quanta when studying the cross-sections such reactions at LUE-40 linac are presented. based on commercially available permanent magnets rectangular cross-sections. maximum on-axis field 0.9 T, which provides sufficient separation electron gamma rays distance more than 90 mm from magnet.
منابع مشابه
Artificial Intelligence Systems for Electron Beam Parameters Optimisation at the Australian Synchrotron Linac∗
We report the development of an artificial intelligent (AI) system for the optimisation of electron beam parameters at the Australian Synchrotron Linac. The system is based on state of the art developments in Artificial Intelligence for video games and is adapted here to beam parameters optimisation problems. It consists of a genetically evolved neural network that mimics an operator’s decision...
متن کاملLinac Coherent Light Source Electron Beam Collimation∗
This paper describes the design and simulation of the electron beam collimation system in the Linac Coherent Light Source (LCLS). Dark current is expected from the gun and some of the accelerating cavities. Particle tracking of the expected dark current through the entire LCLS linac, from gun through FEL undulator, is used to estimate final particle extent in the undulator as well as expected b...
متن کاملTriumf-vecc Electron Linac Beam Dynamics Optimization
The TRIUMF-VECC Electron Linac is a device for gamma-ray induced fission of actinide targets, with applications in nuclear physics and material science. A phased construction and commissioning scheme will eventually lead to a 50 MeV, 10 mA CW linac based on superconducting RF technology. Using this linac to deliver high intensity electron beams for applications such as an energy-recovered light...
متن کاملOperation of the Linac and the Linac Rf System for the Ion-beam Therapy Center Heidelberg
The Heidelberg Ion Therapy Center HIT is in clinical operation since 2009. It is the first dedicated European particle accelerator for medical treatment. Its central location on the campus of the Heidelberg University Hospital fits perfectly in the clinical everyday life. The accelerator complex consists of a linear accelerator and a synchrotron and is designed for protons and carbon ions, but ...
متن کاملBeam Dynamics Studies for the Hie-isolde Linac at Cern
The upgrade of the normal conducting (NC) Radioactive Ion Beam EXperiment (REX)-ISOLDE heavy ion accelerator at CERN, under the High Intensity and Energy (HIE)ISOLDE framework, proposes the use of superconducting (SC) quarter-wave resonators (QWRs) to increase the energy capability of the facility from 3 MeV/u to beyond 10 MeV/u. A beam dynamics study of a lattice design comprising SC QWRs and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Problems of Atomic Science and Technology
سال: 2022
ISSN: ['1562-6016', '1682-9344']
DOI: https://doi.org/10.46813/2022-139-062