Macroprolactin Detection by Precipitation with Protein A-Sepharose: A Rapid Screening Method Compared with Polyethylene Glycol Precipitation
نویسندگان
چکیده
منابع مشابه
Macroprolactin detection by precipitation with protein A-sepharose: a rapid screening method compared with polyethylene glycol precipitation.
within 21 days. The likelihood ratio for a negative result [(1 sensitivity)/specificity] was 0.59 for birth within 7 days, 0.68 for birth within 14 days, and 0.53 for birth within 21 days. The data in Table 1 are similar to those obtained in previous studies using the ELISA-based assay. Joffe et al. (1 ) reported a NPV of 99.6% and a PPV of 9.1% for 243 patients who delivered within 7 days with...
متن کاملPolyethylene glycol precipitation as a screening method for macroprolactinemia.
To the Editor: Vieira et al. (1) used the Wallac Delfia immunofluorometric assay to demonstrate that macroprolactin is a common cause of apparent hyperprolactinemia, and this confirms our experience (2) and that of others (3). However, their data validating the polyethylene glycol (PEG) precipitation as a screening method for detecting macroprolactinemia are substantially different than ours (2...
متن کاملUltrafiltration – an alternative method to polyethylene glycol precipitation for macroprolactin detection
INTRODUCTION The aim of the study was to evaluate two methods of macroprolactin (MaPRL) detection - precipitation with polyethylene glycol (PEG) and ultrafiltration and to compare these techniques with "gold standard" - gel filtration chromatography (GFC). MATERIAL AND METHODS The study was conducted on 245 patients - 45 with organic and 200 with functional hyperprolactinaemia. In all the sub...
متن کاملHyperprolactinemia: new assay more specific for the monomeric form does not eliminate screening for macroprolactin with polyethylene glycol precipitation.
Prolactin presents important size heterogeneity in terms of circulating molecular forms. Besides the monomer (23kDa), which predominates in healthy subjects as well as in patients with prolactinoma, high molecular forms are also present in low concentrations (1). These high molecular forms include 50 kDa dimers (big prolactin) and also forms with even larger molecular weights (MW>150 kDa), know...
متن کاملAssessment of a method for measuring serum thyroxine by radioimmunoassay, with use of polyethylene glycol precipitation.
We assessed the efficacy of a new thyroxine radioimmunoassay kit (Abott) in which polyethylene glycol is used to separate bound from free hormone. Mean serum thyroxine was 88 +/- 15 (+/-SD) microgram/liter for 96 normal persons. Results for hypothyroid and hyperthyroid persons were clearly separated from those for normal individuals. Women taking oral contraceptive preparations showed variable ...