M-φ CHARACTERISTICS OF STEEL PIPE PILES CONSIDERING LOCAL BUCKLING

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of End Bearing Capacity for Pre-Bored Steel Pipe Piles Using Instrumented Spt Rods

The standard penetration test (SPT) has been widely used because of its usability, economy, and many correlations with soil properties among other factors. In SPT, hammer energy is an important factor to evaluate and calibrate N values. To measure hammer energy, an instrumented SPT rod was developed considering that stress waves transferring on rods during SPT driving are the same as stress wav...

متن کامل

Local and Distortional Buckling of Cold-Formed Steel Members

Laminar structures have a high post-buckling strength reserve. Cold-formed steel profiles can be taken as a set of thin plate elements. Therefore it is necessary to design this type of profiles taking into account that reserve of strength in post-local buckling modes of failure. The method normally used to design this type of structures is based on the Effective Width concept. The Effective Wid...

متن کامل

Local Buckling Tests on Cold-Formed Steel Beams

C and Z sections are two of the most common cold-formed steel shapes in use today. Accurate prediction of the bending performance of these sections is important for reliable and efficient cold-formed steel structures. Recent analytical work has highlighted discontinuities and inconsistencies in the American Iron and Steel Institute ~AISI! and Canadian Standards Association ~S136! design provisi...

متن کامل

Analysis on Calculated Length for Buckling Stability of Steel Pipe Pile Based on Energy Method

Abstract: According to the Winkler assumption, the form of the pile constraint could be simplified as bottom fixing and top free. Considering the influence from resistance of soil around pile, the equations on calculated length for buckling stability of steel pipe pile when the portions along the pile length were constrained in the uniform foundation and the layered foundation were respectively...

متن کامل

Dynamic Analysis of Plugged Pipe Piles in Clay

An open ended pipe pile can become plugged when sufficient frictional resistance is developed by the inner soil cylinder within the pile (soil plug), thereby preventing further intrusion of the soil into the pile. When plugging occurs in an impact driven pipe pile, a complex interaction between the pile and soil plug takes place, causing the propagating stress wave to undergo an abrupt change. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Japan Society of Civil Engineers, Ser. B3 (Ocean Engineering)

سال: 2017

ISSN: 2185-4688

DOI: 10.2208/jscejoe.73.i_372