Lumbar spine radiography--poor collimation practices after implementation of digital technology.

OBJECTIVES The transition from analogue to digital radiography may have reduced the motivation to perform proper collimation, as digital techniques have made it possible to mask areas irradiated outside the area of diagnostic interest (ADI). We examined the hypothesis that collimation practices have deteriorated since digitalisation. METHODS After defining the ADI, we compared the proportion ...

متن کامل

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation dur...

متن کامل

Beam Collimation during Lumbar Spine Radiography: A Retrospective Study

INTRODUCTION Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient's radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality. OBJECTIVE To assess the quality of beam collimation duri...

متن کامل

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

متن کامل

The effect of breast shielding during lumbar spine radiography

BACKGROUND The aim of the study was to determine the influence of lead shielding on the dose to female breasts in conventional x-ray lumbar spine imaging. The correlation between the body mass index and the dose received by the breast was also investigated. MATERIALS AND METHODS Breast surface dose was measured by thermoluminescent dosimeters (TLD). In the first phase measurements of breast d...

متن کامل