Low-Pass Filter for HV Partial Discharge Testing
نویسندگان
چکیده
منابع مشابه
Low-Pass Filter for HV Partial Discharge Testing
The most common cause of high voltage electric machine malfunction is an electrical failure of the insulation system due to extreme partial discharges activity. The paper discusses the methodology for the construction of a low-pass high voltage filter for partial discharge measurement. It focuses mainly on the shape optimization, using an analytical approach with subsequent verification using t...
متن کاملPartial Discharge (PD) HV and EHV Power Cable Systems
This chapter represents the state of the art at the time of release. Readers are encouraged to consult the link below for the version of this chapter with the most recent release date: Neither NEETRAC, GTRC, any member of NEETRAC or any cosponsor nor any person acting on behalf of any of them: a) Makes any warranty or representation whatsoever, express or implied, i. With respect to the use of ...
متن کاملSemicircular Microstrip Low Pass Filter
This paper presents semicircular microstrip low pass filter with the sharp rejection and wide stop band. The proposed filter design is based on the calculations of filter parameters from traditional Hi-Lo impedance method and is available in the literature of microstrip filter. To further improve the design performance, high impedance lines are magnetically coupled, resulting an attenuation pol...
متن کاملTransistor Low Pass Filter Schematic
So effectively, you can say that the capacitor acts as a low-pass filter when it in a transistor circuit, it blocks the DC and acts as a low impedance path for AC. Official Full-Text Publication: Single Transistor Active Filters: What is Possible and The results presented here fill both a circuit-theoretic gap and an application-oriented gap related to single a case is the low-pass filter numbe...
متن کاملSelf-Adaptive Morphological Filter for Noise Reduction of Partial Discharge Signals
Partial Discharge assessment in the insulation of high voltage equipment is one of the most popular approaches for prevention of the insulation breakdown. In the procedure of thisassessment, noise reduction of partial discharge signals to get the original PD signal for accurate evaluation is inevitable. This denoising process shall be carried out such a way that the main features of the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2018
ISSN: 1424-8220
DOI: 10.3390/s18020482