Low-Overvoltage Microanalysis: an Alternative High Resolution Strategy to Low-Voltage Microanalysis

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Barriers to Quantitative Electron Probe X-Ray Microanalysis for Low Voltage Scanning Electron Microscopy

Low voltage x-ray microanalysis, defined as being performed with an incident beam energy ≤5 keV, can achieve spatial resolution, laterally and in depth, of 100 nm or less, depending on the exact selection of beam energy and the composition of the target. The shallow depth of beam penetration, with the consequent short path length for x-ray absorption, and the low overvoltage, the ratio of beam ...

متن کامل

A Low Voltage High Resolution

A low voltage incremental analog-to-digital converter with a pipelined architecture is presented. Using first order modulators the conversion time is significantly reduced even at low sampling rates while maintaining high resolution. The switched capacitor converter is designed to operate with a 1.8V power supply and uses three pipelined modulators. With careful design and digital correction it...

متن کامل

Low-voltage electron-probe microanalysis of Fe-Si compounds using soft X-rays.

Conventional electron-probe microanalysis has an X-ray analytical spatial resolution on the order of 1-4 μm width/depth. Many of the naturally occurring Fe-Si compounds analyzed in this study are smaller than 1 μm in size, requiring the use of lower accelerating potentials and nonstandard X-ray lines for analysis. Problems with the use of low-energy X-ray lines (soft X-rays) of iron for quantit...

متن کامل

Electron probe microanalysis of Ni-silicides at low voltage: difficulties and possibilities

Interest in the use of EPMA at low voltage has grown considerably in recent years, mainly because of the availability of electron-beam instruments equipped with field-emission guns. However, EPMA at low voltage is marred by both experimental and analytical problems which may affect the accuracy of quantitative results. In the case of the analysis of transition elements, both the emission and ab...

متن کامل

Strategies for Low Accelerating Voltage X-ray Microanalysis of Sub-Micrometer Features with the FE-EPMA

X-ray microanalyses of sub-micrometer features require that a lower accelerating voltage be used. This reduction in the accelerating voltage reduces the penetrating distance of the beam electrons and thereby reduces the analytical volume. Two general strategies have been proposed for achieving the smallest analytical volume. The first approach involves significantly reducing the accelerating vo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microscopy and Microanalysis

سال: 2002

ISSN: 1431-9276,1435-8115

DOI: 10.1017/s1431927602100997