Low level proportional counter for tritium
نویسندگان
چکیده
منابع مشابه
Development of High Pressure Xe Scintillation Proportional Counter for Experiments in ”low-background” Physics
Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The counter can be applied for the experiments in ”low–background” physics which require a low energy threshold. E-mail : akimov [email protected]
متن کاملSCINTILLATION PROPORTIONAL Xe COUNTER WITH WLS FIBER READOUT FOR LOW-ENERGY X-RAYS
A gas Xe based scintillation proportional counter with cylindrical geometry and wavelength shifting (WLS) fiber readout for X-rays of energy 0.5 − 100 keV is proposed. With such a design large sizes and sensitive area of the counter with a fairly well uniformity is possible. The counter could be used for ”dark matter” search and neutrino magnetic moment measurement and for detection of small am...
متن کاملThe C.A.T. Pixel Proportional Gas Counter Detector
A simple geometry of real pixel gas detectors has been evaluated that circumvents the limitations of a microstrips, namely aging, gain drift and flux limitation due to the dielectric charging. A good resolution has been obtained while preserving a large active size and a high gain and counting rate capabilities.
متن کاملCompact Tissue-equivalent Proportional Counter for Deep Space Human Missions
Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable...
متن کاملTwo Level Proportional Hazards
We extend the proportional hazards model to a two level model with a random intercept term and random coeecients. The parameters in the multilevel model are estimated by a combination of EM and Newton-Raphson algorithms. Even for samples of 50 groups, this method produces estimators of the regression coeecient which are approximately unbiased and normally distributed. Two diierent methods, obse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods
سال: 1963
ISSN: 0029-554X
DOI: 10.1016/0029-554x(63)90169-1