Low level proportional counter for tritium

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of High Pressure Xe Scintillation Proportional Counter for Experiments in ”low-background” Physics

Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The counter can be applied for the experiments in ”low–background” physics which require a low energy threshold. E-mail : akimov [email protected]

متن کامل

SCINTILLATION PROPORTIONAL Xe COUNTER WITH WLS FIBER READOUT FOR LOW-ENERGY X-RAYS

A gas Xe based scintillation proportional counter with cylindrical geometry and wavelength shifting (WLS) fiber readout for X-rays of energy 0.5 − 100 keV is proposed. With such a design large sizes and sensitive area of the counter with a fairly well uniformity is possible. The counter could be used for ”dark matter” search and neutrino magnetic moment measurement and for detection of small am...

متن کامل

The C.A.T. Pixel Proportional Gas Counter Detector

A simple geometry of real pixel gas detectors has been evaluated that circumvents the limitations of a microstrips, namely aging, gain drift and flux limitation due to the dielectric charging. A good resolution has been obtained while preserving a large active size and a high gain and counting rate capabilities.

متن کامل

Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions

Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable...

متن کامل

Two Level Proportional Hazards

We extend the proportional hazards model to a two level model with a random intercept term and random coeecients. The parameters in the multilevel model are estimated by a combination of EM and Newton-Raphson algorithms. Even for samples of 50 groups, this method produces estimators of the regression coeecient which are approximately unbiased and normally distributed. Two diierent methods, obse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods

سال: 1963

ISSN: 0029-554X

DOI: 10.1016/0029-554x(63)90169-1