Low-Level Liquid Scintillation Counter Array with Computerized Data Acquisition and Age Calculation Capabilities for 14C Dating
نویسندگان
چکیده
منابع مشابه
Automation of a Beckman liquid scintillation counter for data capture and data-base management
A software package for the automation of a Beckman LS9000 liquid scintillation counter is presented. The package provides effective on-line data capture (with a Perkin Elmer 3230 32-bit minicomputer), database management, audit trail and archiving facilities. Key features of the package are rapid andJlexible data entry, background subtraction, half-life correction, ability to queue several samp...
متن کاملDetermination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملLow Level Liquid Scintillation Counting of Radioactivity in Food Products
The production rate is 7.5 kg isotope C-14 yearly. The C-14 concentration stays approximately constant due to rapid mixing of the atmosphere, although the cosmic intensity is higher at the poles due to the deflection of charged cosmic particles along the magnetic field lines of the earth (corresponding to neutron intensities in the ratio 5:1 at the poles and the equator, respectively). Conseque...
متن کاملOptimization and Calibration of a Low-background Liquid Scintillation Counter for the Simultaneous Determination of Alpha
The use of low-background liquid scintillation counting (ISC) techniques permits the simultaneous measurement of both alpha and beta emitters with efficiencies close to 100%. In this study, the counting parameters of a Wallac 1220TM Quantulus IS counter have been optimized for the best possible separation of the a and 3 spectra when measuring a sample containing 8 ml of water and 12 ml of Optip...
متن کاملLiquid-Scintillation Counting of 14C-Labelled Animal Tissues
Developments of liquid-scintillation counting as a practical method for the assay of radioisotopes in biological samples followed work by Reynolds, Harrison & Salvini (1950) and Kailmann & Furst (1950). Reviews of progress and developments in liquid-scintillation counting have been given by Davidson & Fiegelson (1957) and Bell & Hayes (1958). Guinn (1958) and Stitch (1959) have reviewed the adv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiocarbon
سال: 1995
ISSN: 0033-8222,1945-5755
DOI: 10.1017/s0033822200031325