This paper introduces a Transimpedance Amplifier (TIA) design capable of producing an incremental input resistance in the ohmic range, for signals microampere such as are encountered instrumentation electrochemical ampero-metric sensors, optical-sensing and current-mode circuits. low input-resistance is achieved using stage incorporating negative feedback. In Cadence simulation exemplary 180 nm CMOS process operating with ± 1.8 V supply rails, 1.05 ohms power dissipation 93.6 µW. The bandwidth, gain 100 dBohm, exceeded 9 MHz. For 1µA, 1 MHz sinusoidal signal Total Harmonic Distortion, this gain, less than 1%. referred noise current zero photodiode capacitance 2.09 pA/√Hz 2pF 8.52 pA/√Hz. Graphical data presented to show effect varying from 0.5 2 pF, when TIA used optical sensing. summary, required very resistance, at level (µA) furthermore Table included comparing characteristics widely Figure Merit (FOM) proposed similar published low-power TIAs. It apparent that FOM better FOMs other TIAs mentioned.
منابع مشابه
Low Noise Low Power Transimpedance Amplifier in 0.18μm Cmos Technology
Low noise and low Power transimpedance amplifiers (TIA) are essential modules for optical sensor based systems. But low power and low noise TIAs are still a challenge for the scientists despite of rapid advances in complementary metal oxide semiconductor (CMOS) technology. This paper proposes a three-stage nested miller compensated (NMC) based design of low noise low power transimpedance amplif...
متن کاملA Low-Voltage, Low-Power, Two-Stage Amplifier for Switched-Capacitor Applications in 90 nm CMOS Process
Abstract- A novel low-voltage two-stage operational amplifier employing resistive biasing is presented. This amplifier implements neutralization and correction common mode stability in second stage while employs capacitive dc level shifter and coupling between two stages. The structure reduces the power consumption and increases output voltage swing. The compensation is performed by simple mill...
متن کاملLow-cost Vector Network Analyzer for Biomedical Applications
A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...
متن کاملWideband Wireless Power Transmission to Enhance Efficiency for Low Input Power for Biomedical Applications
متن کامل
Design of a Current Mirror Based Differential Amplifier for Low-voltage and Low Power Applications
As per the Moore’s law, there is an extreme increase in number of on chip devices, this increase in chip density results in power dissipation and thus the power utilization is unsatisfactory. So to avoid this problem the concept of Low Power system arises. As a part of microelectronics, it has been proposed to make the choice of minute circuit with attraction added by use of MOS cells. Since we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analog Integrated Circuits and Signal Processing