Low-Energy Plasma Focus Device as an Electron Beam Source
A low-energy plasma focus device was used as an electron beam source. A technique was developed to simultaneously measure the electron beam intensity and energy. The system was operated in Argon filling at an optimum pressure of 1.7 mbar. A Faraday cup was used together with an array of filtered PIN diodes. The beam-target X-rays were registered through X-ray spectrometry. Copper and lead line ...
متن کاملRange Distributions of Low-energy Nitrogen and Oxygen Ions in Silicon (RESEARCH NOTE)
The range distributions of low-energy nitrogen and oxygen (2-3 keV) ions is silicon are measured and compared with these available in theories. The nitrogen distribution is very close to a Gaussian distribution as predicted by theory. The oxygen profile however, indicates a surface localized peak along with a shoulder and a long tail into the sample. The surface peak is beleived to he the resul...
متن کاملLow-energy point source searches with IceCube
Due to the overwhelming background of atmospheric muons, the traditional IceCube point source search in the Southern Hemisphere is mainly sensitive to neutrinos with energies above 100TeV. A new approach focuses on events starting inside the instrumented volume. By utilizing different veto techniques we are able to significantly reduce the energy threshold and can now for the first time explore...
متن کاملApplication of a Pulsed , RF - driven ) Multicusp Source for Low Energy Plasma Immersion Ion Implantation
The multicusp ion source has the capability of producing large volumes of uniform, quiescent, high density plasmas. Due to the versatility of the multicusp source, a plasma chamber suited for plasma immersion ion implantation (PIII) was readily constructed. Conventional PIII pulses the bias voltage applied to the substrate which is immersed in a CW mode plasma. However, in the interest of findi...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2007
ISSN: 0034-6748