Low-Energy Electron Diffractive Imaging
نویسندگان
چکیده
منابع مشابه
Low Energy Electron Microscopy (LEEM) Imaging of a Neuron Network
The feasibility of using the LEEM technique in neurobiology was tested with experiments on a rat cerebellar granule cell culture. A series of goodquality images, showing h e details such as axons and dendrites of the neuron network, demonstrate that the test was successful. A new series of microscopy techniques is being developed, with complementary techniques and considerable advantages in lif...
متن کاملLow-energy electron potentiometry.
In a lot of systems, charge transport is governed by local features rather than being a global property as suggested by extracting a single resistance value. Consequently, techniques that resolve local structure in the electronic potential are crucial for a detailed understanding of electronic transport in realistic devices. Recently, we have introduced a new potentiometry method based on low-e...
متن کاملAtom-scale ptychographic electron diffractive imaging of boron nitride cones.
Ptychographic coherent diffractive imaging (CDI) has been extensively applied using both x rays and electrons. The extension to atomic resolution has been elusive. This Letter demonstrates ptychographic electron diffractive imaging at atomic resolution, permitting identification of structure in a boron nitride helical cone at a resolution of order 1 Å, beyond that of comparative Z-contrast imag...
متن کامل10-kV diffractive imaging using newly developed electron diffraction microscope.
A new electron diffraction microscope based on a conventional scanning electron microscope (SEM), for obtaining atomic-level resolution images without causing serious damage to the specimen, has been developed. This microscope in the relatively low-voltage region makes it possible to observe specimens at suitable resolution and record diffraction patterns. Using the microscope we accomplished 1...
متن کاملEffective Pattern Intensity Artifacts Treatment for Electron Diffractive Imaging
We present a method to treat spurious intensities in electron diffraction experiments. Coherent electron diffraction imaging requires proper data reduction before the application of phase retrieval algorithms. The presence of spurious intensities in the electron diffraction patterns makes the data reduction complicated and time consuming and jeopardizes the application of mathematical constrain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nihon Kessho Gakkaishi
سال: 2013
ISSN: 0369-4585,1884-5576
DOI: 10.5940/jcrsj.55.350