Low-cost portable system for measuring thermal conductivity of building

نویسندگان

چکیده

Abstract The developed system allows to measure the thermal conductivity of solid materials used as insulators in building bioclimatic houses on high Andean zones. A unidirectional heat flow model through a sample dimensions 4.0 cm x 4.2 1.35 has been considered. K-type thermocouples were temperature’s gradient. obtained values were: 0.97 Wm −1 °C for glass, 0.38 ignimbrite, 0.58 roof brick and 0.34 adobe with Stipa ichu . These have evaluated considering their abundance use house Arequipa department

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Thermal Conductivity by Ångstrom’s Method

In this experiment, κ, the thermal conductivity of a rod of brass, was measured by periodically heating one end of the rod. Turning the heater attached to the rod on and off with a 10 mHz square wave signal, waves of heat were sent along the length of the rod, measured by two thermistors a distance ∆x apart. Taking these temperatures as a function of time, a Fourier transform was applied to a 1...

متن کامل

Experimental Setup for Measuring the Thermal Conductivity of Pressurized Solutions

Knowledge about the thermal conductivity is expedient whenever heat transport is involved in a process. As pressure plays an important role in a multitude of treatments or reactions, conductivity measurements have also been carried out under pressure for various substances (e. g. lubricants, plant oils and several foods). Experimental data are needed as this property cannot be derived from equa...

متن کامل

A portable measuring system for robot calibration

Currently, much production time is lost in teaching and re-teaching robot programs. New techniques that avoid this, such as off-line programming, require an accurate kinematic model of the robot. To construct this model, measurements of the robot are required. At the University of Amsterdam a self-calibrating measuring system has been developed, using a camera mounted in the robot hand and a re...

متن کامل

Thermal-insulation performance of low density polyethylene (LDPE) foams: Comparison between two radiation thermal conductivity models

The loss of energy especially in industrial and residential buildings is one of the main reasons of increased energy consumption. Improving the thermal insulation properties of materials is a fundamental method for reducing the energy losses. Polymeric foams are introduced as materials with excellent thermal insulation properties for this purpose. In the present study, a deep theoretical invest...

متن کامل

A low-cost pose-measuring system for robot calibration

A low-cost measuring system; printed Wed, A ug 6, 1997 2 1. Abstract To maintain robot accuracy, calibration equipment is needed. In this paper we present a self-calibrating measuring system based on a camera in the robot hand plus a known reference object in the robot workspace. A collection of images of the reference object is obtained. Using image-processing, image-recognition and photogramm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2180/1/012002