Long-term results of custom-made femoral stems
نویسندگان
چکیده
منابع مشابه
Mid-term results of a custom-made short proximal loading femoral component.
Bone preservation and physiological distribution of forces on the proximal femur are key elements in introducing a successful uncemented total hip replacement. In order to achieve this, in the mid 1990s, we developed an ultra short proximal loading custom-made component with a lateral flare, a high femoral neck osteotomy and without a diaphyseal stem. We report the outcome of 129 custom-made hy...
متن کاملPeriprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
BACKGROUND AND PURPOSE Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on p...
متن کاملLong-term Results of Osteoarticular Allograft Reconstruction in Children with Distal Femoral Bone Tumors
Background: There is no consensus regarding the best method of reconstruction in pediatric population following thewide resection of malignant bone tumors. More exploration of the complications of osteoarticular reconstruction leads toless existing controversy of this type of reconstruction, which is the main point of this article.Methods: Long-term outcomes and complications of osteoarticular ...
متن کاملlong-term follow-up results of delayed fixation of femoral neck fractures in adults
conclusions time plays an important role in treatment results of femoral neck fractures. to treat the fractures, closed reduction and fixation using cannulated screws may still be the best option. objectives the present study aimed to evaluate long-term results of delayed fixation of femoral neck fractures using cannulated screws. patients and methods this retrospective descriptive-analytical s...
متن کاملFemoral stem fixation. An engineering interpretation of the long-term outcome of Charnley and Exeter stems.
The excellent long-term results for the first-generation Charnley stem may not apply to later versions with flanges. It seems possible that the early design functioned as a taper-slip system, as accepted in the Exeter prosthesis. Comparison with the requirements for the alternative composite-beam system for the femoral component shows considerable differences that have important implications. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Der Orthopäde
سال: 2020
ISSN: 0085-4530,1433-0431
DOI: 10.1007/s00132-020-03901-z