Long-term Results in 1375 Patients Undergoing Valve Replacement with the Starr-Edwards Cloth-covered Steel Ball Prosthesis
نویسندگان
چکیده
منابع مشابه
Valve dysfunction of the cloth-covered Starr-Edwards ball valve.
BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...
متن کاملImpaired function of cloth-covered Starr-Edwards mitral valve prosthesis. Detection by phonocardiography.
was suspected because of phonocardiographic abnormalities. A prolonged interval from aortic closure to opening of the mitral ball suggested an impediment to movement of the ball. This was confirmed by catheterization and cinefluorography. At autopsy the impaired ball movement was found to be due to thrombus buildup on the outflow face of the mitral valve orifice. It is suggested that frequent p...
متن کاملFixation of aortic ball valve prosthesis (Starr-Edwards).
The technique of fixation of a ball valve prosthesis in the area of the non-coronary cusp by bringing the sutures from the collar of the prosthesis out through the wall of the aorta and tying them over strips of dacron has been discussed by Starr, Edwards, McCord, and Griswold (1963), and advocated by Effler, Groves, and Favaloro (1964). We have never in our first 100 operated cases seen a leak...
متن کاملResults after mitral valve replacement with cloth-covered Starr-Edwards prostheses (models 6300, 6310/6320, and 6400).
The actuarial survival and thromboembolic rates for the three types of cloth-covered Starr-Edwards mitral prostheses, models 6300, 6310/6320, and 6400 followed 6, 5, and 2 years, respectively, were not significantly different throughout the years they were followed. The combined cumulative survival and thromboembolic proportion at 5 years for these prostheses were 71 and 66 per cent, respective...
متن کاملLong-term prognosis of mitral or aortic valve replacement by a Starr-Edwards prosthesis.
A Swr-Edwards Silsstic hd-valve prosthesis was inserted in 100 seriously d l M e d patients with isolated aortic (55 case) or m i l d (45 caws) valve dbease. The follow-up study for periods of Urree years or more resulted in the following points. The o v e d mortslity rate reached 35 percent in both groups. but the operative risks were t h m times lea in the mrtic thno in the m i i d group. Thr...