Long-range parametric amplification of THz wave with absorption loss exceeding parametric gain
نویسندگان
چکیده
منابع مشابه
Efficient Long Range Communication by Quantum Injected Optical Parametric Amplification
Free-space optical communications over long distances are associated with severe losses while the natural limit for the energy associated to a single bit of information is just one photon. In order to enhance the transmission Efficiency we propose the use of macro qubits consisting of thousand of photons. We investigate the Fidelity of the transmission of a macro-qubit generated by quantum inje...
متن کامل1 Terahertz - Wave Parametric Generator ( TPG ) / Pumping source 1 . 1 Injection - seeded THz - wave Parametric Generator
Coherent tunable terahertz (THz) waves were successfully generated using an injection-seeded THz-wave parametric generator (TPG) based on laser light scattering from the A1-symmetry polariton mode of MgO:LiNbO3 crystals. THz-wave spectrum narrowing to the Fourier transform limit was achieved by injection seeding the idler wave (near-infrared Stokes). This resulted in a THz-wave output approxima...
متن کاملParametric Amplification of a Superconducting Plasma Wave
Many applications in photonics require all-optical manipulation of plasma waves1, which can concentrate electromagnetic energy on sub-wavelength length scales. This is difficult in metallic plasmas because of their small optical nonlinearities. Some layered superconductors support Josephson plasma waves (JPWs)2,3, involving oscillatory tunneling of the superfluid between capacitively coupled pl...
متن کاملContinuous - wave phase - sensitive parametric image amplification
(Received 00 Month 200x; In final form 00 Month 200x) We study experimentally parametric amplification in the continuous regime using a transverse-degenerate type-II Optical Parametric Oscillator operated below threshold. We demonstrate that this device is able to amplify either in the phase insensitive or phase sensitive way first a single mode beam, then a multimode image. Furthermore the tot...
متن کاملHigh-temporal contrast using low-gain optical parametric amplification.
We demonstrate the use of low-gain optical parametric amplification (OPA) as a means of improving temporal contrast to a detection-limited level 10(-10). 250 microJ, 500 fs pulses of 1053 nm are frequency doubled and subsequently restored to the original wavelength by OPA with >10% efficiency.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2013
ISSN: 1094-4087
DOI: 10.1364/oe.21.002452