Long length HTS cable with integrated FCL property

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magneto-thermal finite element modeling of 2nd generation HTS for FCL design purposes

Coated conductors are very promising for the design of novel and efficient Fault Current Limiter (FCL). However, before considering using them in a power grid, their thermal and electromagnetic behaviors in the presence of over-critical currents need to be investigated in details. In this context, we performed finite element magneto-thermal modeling of coated conductors under over-critical curr...

متن کامل

Technical and Economical Impacts on a Power System by Introducing an HTS FCL

Fault current limiters (FCLs) can be considered as key elements in power systems using high temperature superconductors. This analysis takes into account the system benefits provided by the introduction of FCLs in various network configurations. New meshing possibilities, alternative grounding method and increase of power transmission are highlighted. It is the desire of most power system utili...

متن کامل

Active length of cable lines with uncoated metal sheaths as long grounding conductors

Power cables that have sheaths, usually lead, and are manufactured with bitumen impregnated hessian which degrades over time, act as long grounding electrodes or inject fault current directly into the surrounding soil. As a consequence of this, the MV lines made of this type of cable spontaneously form a very large and complex grounding system around the high-voltage/medium-voltage (HV/MV) dist...

متن کامل

Distance and Cable Length Measurement System

A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with ...

متن کامل

Tri-axial Core Design of a Distribution System Class HTS Power Cable

A tri-axial HTS power cable has been proposed and developed to reduce the number of HTS wires because it has copper shield instead of HTS shield. However, it has a drawback which is an inherent imbalance problem due to an asymmetry configuration in the cable. The authors designed a 22.9 kV/50 MVA class tri-axial HTS cable. The inherent imbalance problem of the three-phase currents in the tri-ax...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2010

ISSN: 1742-6596

DOI: 10.1088/1742-6596/234/3/032037