Logarithmic Computer‐Plotter for Mechanical and Acoustical Impedances
نویسندگان
چکیده
منابع مشابه
Optimal inequalities for the power, harmonic and logarithmic means
For all $a,b>0$, the following two optimal inequalities are presented: $H^{alpha}(a,b)L^{1-alpha}(a,b)geq M_{frac{1-4alpha}{3}}(a,b)$ for $alphain[frac{1}{4},1)$, and $ H^{alpha}(a,b)L^{1-alpha}(a,b)leq M_{frac{1-4alpha}{3}}(a,b)$ for $alphain(0,frac{3sqrt{5}-5}{40}]$. Here, $H(a,b)$, $L(a,b)$, and $M_p(a,b)$ denote the harmonic, logarithmic, and power means of order $p$ of two positive numbers...
متن کاملOptimal Virtual Mechanical Impedances Ap- Proach for the Vibroacoustic Active Con- Trol of a Panel
In order to reduce the acoustic power radiated by a structure, co-located actuator and sensor pairs are used to virtually implement local mechanical impedance. For each pair, at each frequency of interest, the virtual mechanical impedance is a complex value which imposes a linear relationship between the dual local variables of the actuator input and the sensor output. The optimal virtual mecha...
متن کاملWall Impedances for Low and Moderate Energies
Properties of the wall impedance of a storage ring are studied for a low relativism, 1 1: Both broad and narrow band impedances are shown to be damped at low energies, the damping factors are found. Coherent motion of a coasting beam is discussed; Landau decrements are calculated.
متن کاملRespiratory input and transfer mechanical impedances in patients with chronic obstructive pulmonary disease.
Total respiratory input (Zin) and transfer (Ztr) mechanical impedances were measured from 4-30 Hz in 9 patients with severe chronic obstructive pulmonary disease (COPD) and in 12 healthy subjects. Zin was obtained by applying a pressure input around the head to minimize transmural pressure across extrathoracic airway walls, and Ztr was obtained with a pressure input at the chest. In agreement w...
متن کاملPartitioning of airway and respiratory tissue mechanical impedances by body plethysmography.
We have tested the feasibility of separating the airway (Zaw) and tissue (Zti) components of total respiratory input impedance (Zrs,in) in healthy subjects by measuring alveolar gas compression by body plethysmography (Vpl) during pressure oscillations at the airway opening. The forced oscillation set up was placed inside a body plethysmograph, and the subjects rebreathed BTPS gas. Zrs,in and t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Acoustical Society of America
سال: 1963
ISSN: 0001-4966
DOI: 10.1121/1.2142716