LOCAL STRENGTHAND STIFFNESS OF NON-DIAPHRAGM CONNECTION OF CHS COLUMN TO BEAM FLANGE
نویسندگان
چکیده
منابع مشابه
Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملFinite element analysis of a rigid beam to column connection reinforced with channels
Abstract: This research work presents a new rigid connection constructed with channels. In order to assess its hysteresis behavior, three specimens with different cover plates and six specimens with different panel zone thickness have been considered. The energy absorbed by the connection and the behavior of the panel zone were studied during cyclic loading and compared with those of connectio...
متن کاملEffect of column-foundation connection stiffness on seismic performance of rocking steel braced frame
Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...
متن کاملstudy on the effect of the first hole distance of beam flange from column face on the seismic behavior of drilled flange connection (dfc)
beam to column welded connection with radius cut on beam flange is known as rigid connection that provides acceptable ductility for special moment resisting frame (smrf). in order to decrease the cost of construction and to provide an easy-to-construct structure, the new method is available for reducing the beam section based on drilling on beam flange , known as drilled flange connection (dfc)...
متن کاملEvaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)
The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2015
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.80.703