Loads in hip disarticulation prostheses during normal daily use

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loads in hip disarticulation prostheses during normal daily use.

As a result of deficiency at birth, disease or trauma, there are people who have no limbs from the hip joint downwards. These people have no possibility of locomotion without the use of other devices such as wheelchairs or hip disarticulation prostheses. As these prostheses are used by people of all ages, people who are different in their grade of physical activities and their weights, the pros...

متن کامل

Endovascular balloon assistance during hip disarticulation

L imb disarticulation has been widely performed since the 18th century, especially in war surgery when reconstructive interventions have not been possible. Actually, limb disarticulation is infrequently done in orthopaedic and vascular surgery, and it is associated with a high mortality rate because of frequent comorbidities. Hip disarticulation usually is reserved for patients with neoplasms o...

متن کامل

Disabilities and Activities of Daily Living Among Veterans With Old Hip Disarticulation and Transpelvic Amputation

BACKGROUND The Iran-Iraq imposed war lasted eight years and was one of the longest wars of the last century. Twenty-three years have passed since the war ended, but little has been discussed about the long-term results of war amputations in the literature. OBJECTIVES In this long-term study, we have evaluated the activities of daily living among veterans with hip or hemipelvis amputations. ...

متن کامل

Use of two-axis joystick for control of externally powered shoulder disarticulation prostheses.

We explored a new method for simple and accurate control of shoulder movement for externally powered shoulder disarticulation prostheses with a two-axis joystick. We tested 10 subjects with intact shoulders and arms to determine the average amount of shoulder motion and force available to control an electronic input device. We then applied this information to two different input strategies to e...

متن کامل

Biomechanics of the hip disarticulation prosthesis.

1 Previously published in Orthopadie Technik, 4/76, 58-60. Introduction M o r e than twenty years ago, McLaur in (1954) published his first report on the Canadian hip disarticulation prosthesis. His work was aimed at improving the conventional design of the saucer-type and tilting table prostheses. A measure of his success can be seen in that the Canadian-type has made the other two almost obso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Prosthetics & Orthotics International

سال: 1998

ISSN: 0309-3646

DOI: 10.3109/03093649809164485