Load Modelling for a Federal Medical Center in Nigeria under Erratic Power Supply

نویسندگان

چکیده

Load data of a Federal Medical Center (FMC) in Nigeria, under prevailing erratic power supply from Nigeria’s electric distribution company (DisCo) feeders, were considered to develop model load curve and electricity use values for planning effective management. The analytical methods applied include nominal evaluation the entire FMC, acquisition by direct hourly monitoring 12 months, diesel fuel consumption observation during DisCo outages, energy metering, outage events durations, descriptive statistical evaluations data. results obtained analysed following: load, daily models. established parameters, such as factor, average expected electrical typical Nigerian FMC. Model factor is 0.545, which would be uneconomical especially when using standby generators whole day due failure Disco feeder.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Childhood mortality in federal medical centre umuahia, South eastern Nigeria.

OBJECTIVES This study aimed to evaluate the mortality pattern in children seen at Federal Medical Centre Umuahia (FMCU) Abia state, South Eastern Nigeria. METHODS A retrospective cross sectional descriptive study over a 5-year period from January 1, 2004 to December 31, 2008 using data retrieved from the hospital's medical records department. RESULTS A total of 3,814 children were admitted ...

متن کامل

Testing a power supply for line and load transients

Line and load transients are step functions that inject disturbances into the power supply. A load transient injects disturbance into the output by stepping the load current, and a line transient does so by stepping the line voltage. The supply’s output response demonstrates its ability to attenuate the various frequency components of a line or load step. The following discussion describes thes...

متن کامل

Wireless Load Self-Disconnection Module For Automatic Power Supply System

Nowadays, the use of Auxiliary power supply (APS) systems to energize low power rating appliances (e.g. televisions, water dispensers, etc.) and lighting (e.g. CFL lamps) has become pervasive in countries where long power rationing schemes are applied. Although the existing APS systems offer overload protection, it cannot be directly connected to the existing electric circuit unless heavy loads...

متن کامل

Load Tap Changing Controls as a Power System Nerve Center

Products based on digital technology for the control of LTC transformers and step-voltage regulators are now entering an evolutionary second generation. Ever more sophisticated concepts are being made available as electronic components become available to accommodate the needs in a cost effective manner. Most notably, this provides a realistic opportunity to use the LTC control as a monitor poi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: FUOYE Journal of Engineering and Technology

سال: 2023

ISSN: ['2579-0617', '2579-0625']

DOI: https://doi.org/10.46792/fuoyejet.v8i1.981