Liver Bremsstrahlung Imaging with Pure Beta Emitter
نویسندگان
چکیده
منابع مشابه
Bremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کاملOptimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملPosttherapy radiation safety considerations in radiomicrosphere treatment with 90Y-microspheres.
Radiomicrosphere treatment involves the intrahepatic arterial administration of (90)Y-resin or (90)Y-glass microspheres. The microspheres are biocompatible, but not biodegradable, and little to no (90)Y leaches from the microspheres. Without any bioelimination, the beta-dose delivery is generally confined to the liver. Although U.S. Nuclear Regulatory Commission requirements permit patients tre...
متن کاملPET imaging of brain cancer with positron emitter-labeled liposomes.
Since nanocarriers such as liposomes are known to accumulate in tumors of tumor-bearing animals, and those that have entrapped a positron emitter can be used to image a tumor by PET, we applied (18)F-labeled 100-nm-sized liposomes for the imaging of brain tumors. Polyethylene glycol (PEG)-modified liposomes, which are known to accumulate in tumors by passive targeting and those modified with Al...
متن کاملPolarization Bremsstrahlung in Thick Targets Produced by Continuous Beta Particles
Bremsstrahlung spectral photon distributions produced by continuous beta particles of beta emitter 147Pm and 45Ca in thick targets studied in a photon energy region 10-30 keV. The bremsstrahlung spectral photon distribution measured with X-PIPS Si (Li) detector. The experimental results were compared with the theoretical bremsstrahlung distribution obtained from ordinary bremsstrahlung (OB) the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Medical Sciences
سال: 2014
ISSN: 1682-4474
DOI: 10.3923/jms.2014.210.216