Liquid scintillator response to proton recoils in the 10–100 keV range

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV

The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found to be 0.19±0.02. PACS codes: 29.40.Mc, 78.70.-g, 78.60.-b, 95.35.+d

متن کامل

Development of a liquid scintillator-based 3D detector for range measurements of spot-scanned proton beams

The goal of the present study is to develop a liquid scintillator-based 3D detector and investigate its performance for beam range measurements in real time. The detector design consists of a tank filled with water-equivalent liquid scintillator that scintillates in response to incident proton beams. Three scientific complementary metal-oxide semiconductor (sCMOS) cameras collect the resulting ...

متن کامل

Proton decay in the large liquid scintillator detector LENA: study of the background

Using Geant4 Monte-Carlo simulations the potential of the Low Energy Neutrino Astronomy (LENA) liquid scintillator detector for the investigation of a possible proton decay within the channel p → Kν is discussed. Special emphasis is given to the study of background events.

متن کامل

Quantum mechanical proton range in human body

Introduction: Proton therapy delivers radiation to tumor tissue in a much more confined way than conventional photon therapy thus allowing the radiation oncologist to use a greater dose while still minimizing side.   Materials and Methods: protons release most of their energy within the tumor region. As a result, the treating physician can potentially give an...

متن کامل

MEASUREMENT OF THE SCINTILLATION EFFICIENCY OF Na RECOILS IN NaI(Tl) DOWN TO 10 keV NUCLEAR RECOIL ENERGY RELEVANT TO DARK MATTER SEARCHES

We present preliminary results of measurements of the quenching factor for Na recoils in NaI(Tl) at room temperature, made at a dedicated neutron facility at the University of Sheffield. Measurements have been performed with a 2.45 MeV mono-energetic neutron generator in the energy range from 10 keV to 100 keV nuclear recoil energy. A BC501A liquid scintillator detector was used to tag neutrons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review C

سال: 2018

ISSN: 2469-9985,2469-9993

DOI: 10.1103/physrevc.98.045802