Liquid Nanofilms’ Evaporation Inside a Heat Exchanger by Mixed Convection

نویسندگان

چکیده

The present work focuses on a numerical investigation of nanofilms’ (water/copper and water/aluminium) evaporation inside heat exchanger by mixed convection flowing down one channel plate. was composed two parallel vertical plates. wetted plate heated while the other maintained isothermal dry. impact dispersion different types nanoparticles in liquid film their volume fraction mass exchange process has been analysed this work. results show that an increase nanoparticle inlet enhances efficiency exchangers. It is shown enhancement 22% rate recorded when elevated 5%. water–copper nanofluid had higher compared to water–aluminium nanofluid.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HC-290 (Propane) Vaporisation Inside a Brazed Plate Heat Exchanger

This paper presents the heat transfer coefficients measured during HC-290 (Propane) vaporisation inside a brazed plate heat exchanger: the effects of heat flux, saturation temperature (pressure) and outlet conditions are investigated. The heat transfer coefficients show weak sensitivity to saturation temperature (pressure) and great sensitivity to heat flux and outlet conditions. The saturated ...

متن کامل

Analysis of Heat Transfers inside Counterflow Plate Heat Exchanger Augmented by an Auxiliary Fluid Flow

Enhancement of heat transfers in counterflow plate heat exchanger due to presence of an intermediate auxiliary fluid flow is investigated. The intermediate auxiliary channel is supported by transverse conducting pins. The momentum and energy equations for the primary fluids are solved numerically and validated against a derived approximate analytical solution. A parametric study including the e...

متن کامل

Evaporation and Condensation Heat Transfer Performance of Flammable Refrigerants in a Brazed Plate Heat Exchanger

Average Nusselt numbers were measured for R22, R290, R290/600a, and R32/152a undergoing evaporation and condensation in a brazed plate heat exchanger. The refrigerants experienced wavy, stratified flow at low heat and mass fluxes, 1.3 kW/m2 to 8.3 kW/m2 and 1.6 kg/m2 s to 19 kg/m 2 s, respectively. Heat transfer correlations from the literature for in-tube and channel flow of refrigerants with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Coatings

سال: 2022

ISSN: ['2079-6412']

DOI: https://doi.org/10.3390/coatings12101564