Liquid Chromatography-Tandem Mass Spectrometry in the Clinical Laboratory

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid chromatography-tandem mass spectrometry--application in the clinical laboratory.

This review provides a concise survey of liquid chromatography-tandem mass spectrometry (LC-TMS) as an emerging technology in clinical chemistry. The combination of two mass spectrometers with an interposed collision cell characterizes LC-TMS as an analytical technology on its own and not just as a more specific detector for HPLC compared with conventional techniques. In LC-TMS, liquid chromato...

متن کامل

Liquid chromatography tandem mass spectrometry in the clinical laboratory.

Clinical laboratory medicine has seen the introduction and evolution of liquid chromatography tandem mass spectrometry in routine clinical laboratories over the last 10-15 years. There still exists a wide diversity of assays from very esoteric and highly specialist manual assays to more simplified kit-based assays. The technology is not static as manufacturers are continually making improvement...

متن کامل

Pitfalls associated with the use of liquid chromatography-tandem mass spectrometry in the clinical laboratory.

BACKGROUND Novel mass spectrometric techniques such as atmospheric pressure ionization and tandem mass spectrometry have substantially extended the spectrum of clinical chemistry methods during the past decade. In particular, liquid chromatography tandem-mass spectrometry (LC-MS/MS) has become a standard tool in research laboratories as well as in many clinical laboratories. Although LC-MS/MS h...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Chromatography & Separation Techniques

سال: 2013

ISSN: 2157-7064

DOI: 10.4172/2157-7064.1000e115