Linear combination steady-state free precession MRI
نویسندگان
چکیده
منابع مشابه
Linear combination steady-state free precession MRI.
A new, fast, spectrally selective steady-state free precession (SSFP) imaging method is presented. Combining k-space data from SSFP sequences with certain phase schedules of radiofrequency excitation pulses permits manipulation of the spectral selectivity of the image. For example, lipid and water can be resolved. The contrast of each image depends on both T1 and T2, and the relative contributi...
متن کاملSpin Locked Steady-State Free Precession Imaging
Introduction: T1ρ MRI is typically performed by magnetization preparation followed by a readout sequence during which the T1ρ-weighted signal is frequency and phase encoded (1). This paradigm is inherently time inefficient and, instead, it might be desirable to continuously acquire the T1ρ-weighted signal in the steady-state. Unfortunately, it isn’t clear how to establish a steady-state T1ρ con...
متن کاملMR angiography using steady-state free precession.
Contrast-enhanced MR angiography (CE-MRA) using steady-state free precession (SSFP) pulse sequences is described. Using SSFP, vascular structures can be visualized with high signal-to-noise ratio (SNR) at a substantial (delay) time after the initial arterial pass of contrast media. The peak blood SSFP signal was diminished by <20% 30 min after the initial administration of 0.2 mmol/kg of Gd-che...
متن کاملResting-State fMRI Using Passband Balanced Steady-State Free Precession
OBJECTIVE Resting-state functional MRI (rsfMRI) has been increasingly used for understanding brain functional architecture. To date, most rsfMRI studies have exploited blood oxygenation level-dependent (BOLD) contrast using gradient-echo (GE) echo planar imaging (EPI), which can suffer from image distortion and signal dropout due to magnetic susceptibility and inherent long echo time. In this s...
متن کاملSpectrally selective imaging with wideband balanced steady-state free precession MRI.
PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2000
ISSN: 0740-3194,1522-2594
DOI: 10.1002/(sici)1522-2594(200001)43:1<82::aid-mrm10>3.0.co;2-9