Linear combination of multiecho data: Short T 2 component selection
نویسندگان
چکیده
منابع مشابه
Combination of Feature Selection and Learning Methods for IoT Data Fusion
In this paper, we propose five data fusion schemes for the Internet of Things (IoT) scenario,which are Relief and Perceptron (Re-P), Relief and Genetic Algorithm Particle Swarm Optimization (Re-GAPSO), Genetic Algorithm and Artificial Neural Network (GA-ANN), Rough and Perceptron (Ro-P)and Rough and GAPSO (Ro-GAPSO). All the schemes consist of four stages, including preprocessingthe data set ba...
متن کاملReal-time quantification of T(2)(*) changes using multiecho planar imaging and numerical methods.
Conventional approaches to quantify whole brain T(2)(*) maps use nonlinear regression with intensive computational requirements that therefore likely limit quantitative T(2)(*) mapping for real-time applications. To overcome these limitations an alternative method, NumART(2)(*) (NUMerical Algorithm for Real-time T(2)(*) mapping) that directly calculates T(2)(*) by a linear combination of images...
متن کاملSelection of Relevant Nodes from Component-Trees in Linear Time
Component-trees associate to a discrete grey-level image a descriptive data structure induced by the inclusion relation between the binary components obtained at successive level-sets. In this work we propose a method to extract a subset of the component-tree of an image enabling to fit at best a given binary target selected beforehand in the image. A proof of the algorithmic efficiency of this...
متن کاملSelection of a Multistep Linear Predictor for Short Time Series
We develop a version of the Corrected Akaike Information Criterion (AICC) suitable for selection of an h-step-ahead linear predictor for a weakly stationary time series in discrete time. A motivation for this criterion is provided in terms of a generalized Kullback-Leibler information which is minimized at the optimal h-step predictor, and which is equivalent to the ordinary Kullback-Leibler in...
متن کاملBrain morphometry with multiecho MPRAGE
In brain morphometry studies using magnetic resonance imaging, several scans with a range of contrasts are often collected. The images may be locally distorted due to imperfect shimming in regions where magnetic susceptibility changes rapidly, and all scans may not be distorted in the same way. In multispectral studies it is critical that the edges of structures align precisely across all contr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2004
ISSN: 0740-3194
DOI: 10.1002/mrm.10713