Linear attenuation coefficient measurement in polymer composite
نویسندگان
چکیده
منابع مشابه
Application of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding
Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...
متن کاملAnalysis of the Attenuation Coefficient of Composite Silicone Rubber and Gliceryn for Soft Tissue Phantom Applications
Introduction: Phantom is an object that can be used to investigate the accuracy of radiation dose delivered to patients. Phantom is usually produced from the combination of the silicone rubber as a matrix and glycerin as a filler to form a composite for the replacement of the human soft tissue. The composite is imaged using computed tomography (CT) simulator for the de...
متن کاملAn Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values...
متن کاملImage Indexing And Retrieval Using Linear Phase Coefficient Composite Filters
Content-based retrieval techniques can be characterized in several ways: by the manner in which image data are indexed, by the level of specificity/generality of the query and response of the system, by the type of query (e.g., iconic or symbolic), and by the kind of information used (intrinsic image features or attached information such as text). The method described in this paper automaticall...
متن کاملMeasurement of linear and mass attenuation coefficient of alcohol soluble compound for gamma rays at energy 0.511 MeV
Linear and mass attenuation of 0.511 MeV gamma radiations from alcohol ethanol by dilute solution of Phenol (C6H6O) studied for different concentrations. Mixture rule for theoretical calculation of attenuation coefficient is developed for the solution; our study explores the validity of the expected exponential absorption law for γ-rays radiations in solution and also provides an alternative me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Iraqi Journal of Physics (IJP)
سال: 2019
ISSN: 2664-5548,2070-4003
DOI: 10.30723/ijp.v12i25.299