Limiting Reinforcement Ratios for Hybrid GFRP/Steel Reinforced Concrete Beams

نویسندگان

چکیده

In this work, a theoretical approach is proposed for estimating the minimum and maximum reinforcement ratios hybrid glass fiber reinforced polymer (GFRP)/steel-reinforced concrete beams to prevent sudden brittle failure as well compression of before tension reinforcements. Equilibrium equations were used develop method determining GFRP/steel ratio. A ratio was also developed based on equilibrium forces balanced mode. For load-carrying capacity with GFRP/steel, less than more recommended. Comparisons between expressions, experimental data, available test results in literature shows good agreement discrepancy 7%.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shear Strength of Slender Reinforced Concrete Beams without Web Reinforcement

This paper attempt to predict the shear strength of high strength concrete beam with different shear span of depth ratio without web reinforcement. The large data base available has been clustered and a linear equation analysis has been performed . The prepared models are functions of compressive strength , percentage of flexural reinforcement and depth of beam. The proposed models have been va...

متن کامل

Reliability evaluation of reinforced concrete beams

The purpose of this paper is to evaluate the time-invariant reliability of reinforced concrete beams designed under the provisions of the ACI Building Code. A wide range of practical design situations is considered. The beams are subjected to bending, shear, and torsion. The interaction between shear and torsion is considered via an elliptical failure surface defined in the shear-torsion stress...

متن کامل

Influence of shear reinforcement corrosion on the performance of under-reinforced concrete beams

Reinforced concrete beams are normally designed as under-reinforced to provide ductile behaviour at failure i.e. the tensile moment of resistance, Mt(0), is less than the moment of resistance of the compressive zone, Mc. Since it is well established that the steel in reinforced concrete beams is prone to corrosion, the residual flexural strength is normally the main concern of asset managers. H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Engineering and Technology Innovation

سال: 2021

ISSN: ['2226-809X', '2223-5329']

DOI: https://doi.org/10.46604/ijeti.2021.6660