Limited-Angle Computer Tomography with Truncated Projection Artifacts Removal

نویسندگان

چکیده

Breast cancer is the most common in women and second world. Digital breast tomosynthesis (DBT) an effective medical imaging method. It can reduce overlap of tissue reconstructed images, which beneficial to early detection cancer. DBT uses projection data from a limited range angles simultaneous algebraic reconstruction technique (SART) based Since detector’s field view (FOV) limited, updates large SART cannot include all voxels target, causes truncated artifacts (TPA) at edges image. In this work, we use images by perform re-projection on virtually expanded detector panel gradient calculation method compensate for missing ensure that each update voxels. Experiments simulation human demonstrated TPA be effectively reduced while retaining detailed structure, thus improving image quality border recovering obscured structural information. might provide better result consequential clinical diagnosis.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exact Interior Reconstruction from Truncated Limited-Angle Projection Data

Using filtered backprojection (FBP) and an analytic continuation approach, we prove that exact interior reconstruction is possible and unique from truncated limited-angle projection data, if we assume a prior knowledge on a subregion or subvolume within an object to be reconstructed. Our results show that (i) the interior region-of-interest (ROI) problem and interior volume-of-interest (VOI) pr...

متن کامل

Characterization and reduction of artifacts in limited angle tomography

We consider the reconstruction problem for limited angle tomography using filtered backprojection (FBP) and Lambda tomography. We use microlocal analysis to explain why the well-known streak artifacts are present at the end of the limited angular range. We explain how to mitigate the streaks and prove that our modified FBP and Lambda operators are standard pseudodifferential operators, and so t...

متن کامل

Limited-projection-angle hybrid fluorescence molecular tomography of multiple molecules.

An advantage of fluorescence methods over other imaging modalities is the ability to concurrently resolve multiple moieties using fluorochromes emitting at different spectral regions. Simultaneous imaging of spectrally separated agents is helpful in interrogating multiple functions or establishing internal controls for accurate measurements. Herein, we investigated multimoiety imaging in the co...

متن کامل

Limited Angle Tomography Using Volumetric Constraints

Earth with 4 station receiver chain The ionosphere lies approximately in the 80 — 500 km altitude range. As the satellite passes over head it sends dual frequency radio signals at 150 and 400 MHz respectively which undergo different amounts of Doppler phase shift along each ray path before they are simultaneously received by the ground stations. The difference of Doppler shift encountered by ea...

متن کامل

TGV sinogram inpainting for limited angle tomography

X-ray computed tomography (CT) plays a very important role in daily biomedical practice for diagnosis and therapy, and in materials science for accurate data analysis and quality control. Besides accurate and robust image reconstruction, there is a growing interest in methods for limited angle tomography. The idea is to reduce the X-ray dose delivered to patients or to cope with physical angle ...