BACKGROUND Altitude and gravity changes during aeromedical evacuations induce exacerbated cardiovascular responses in unstable patients. Non-invasive cardiac output monitoring is difficult to perform in this environment with limited access to the patient. We evaluated the feasibility and accuracy of stroke volume estimation by finger photoplethysmography (SVp) in hypergravity. METHODS Finger ...
متن کاملdesign and implementation of a portable impedance cardiograph system for non-invasive stroke volume monitoring
measurement of the stroke volume and its changes over time can be very helpful for diagnosis of dysfunctions in the blood circulatory system and monitoring their treatments. impedance cardiography (icg) is a simple method of measuring the stroke volume based on changes in the instantaneous mean impedanceof the thorax. this method has received much attention in the last two decades because it is...
متن کاملBlood Pressure Estimation with Considering of Stroke Volume Effect
The mean arterial pressure (MAP) is a very important cardiovascular parameter for physicians to diagnose various cardiovascular diseases. Many algorithms were used to estimate MAP with different accuracy. These algorithms used different factors, such as blood level, pulses, and external applied pressure, photo-plethysmography (PPG) signal features, heart rate (HR), and other factors. In additio...
متن کاملNon Invasive Estimation of End-systolic Blood Pressure in Babies
Conventional measurements of systolic cardiac function and cardiac output may be influenced by loading conditions. The presence of extra-cardiac shunts in the transitional circulation limits the application of such measures in a neonatal population. An accurate method to assess neonatal myocardial function is required that takes account of cardiac loading conditions. One option is to correlate ...
متن کاملContinuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress.
The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and evaluated whether, under orthostatic stress, flow may be derived from both an invasive and a non-i...