Limitations of Current Polarization for Lowering the Detection Limit of Potentiometric Polymeric Membrane Sensors
نویسندگان
چکیده
منابع مشابه
Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
متن کاملpolymeric membrane sensor for potentiometric determination of tin(ii) ions
tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...
متن کاملstudy of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
the use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach
abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...
15 صفحه اولPVC Membrane Sensors for Potentiometric Determination of Acebutolol
The construction and general performance characteristics of two novelpotentiometric membrane sensors responsive to the acebutolol are described. Thesensors are based on the use of ion-association complexes of acebutolol (AC) withtetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVCmatrix. The sensors show a fast, stable and near- Nernstian for the mono charge catio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Chemistry
سال: 2009