LIMIT STATES AND FAILURE CRITERIA FOR EARTHQUAKE RESISTANT STRUCTURES
نویسندگان
چکیده
منابع مشابه
Criteria for Seismic Risk Reduction of Earthquake Resistant Buildings
Most of the existing seismic design codes are based on the empirical knowledge accumulated through systematic earthquake damage data collection and their analysis. Required levels of protection and seismic design forces gradually are increased after each series of catastrophic earthquakes particularly in developed countries. Many efforts have been made through experimental and analytical studie...
متن کاملInnovations in Earthquake Resistant Steel Structures
This paper reviews selected recent innovations that expand the range of applicability of a number of new and emerging structural steel systems that can provide effective seismic performance. Focus is on recent developments on: (a) Steel Plate Shear Walls having light gauge infill plates; (b) Perforated Steel Plate Shear Walls; (c) Buckling Restrained Braced frames designed to meet Structural Fu...
متن کاملFUZZY IDEALS AND FUZZY LIMIT STRUCTURES
In this paper, we establish the theory of fuzzy ideal convergence on completely distributive lattices and give characterizations of some topological notions. We also study fuzzy limit structures and discuss the relationship between fuzzy co-topologies and fuzzy limit structures.
متن کاملApproximate Dynamic Analysis of Structures for Earthquake Loading Using FWT
Approximate dynamic analysis of structures is achieved by fast wavelet transform (FWT). The loads are considered as time history earthquake loads. To reduce the computational work, FWT is used by which the number of points in the earthquake record are reduced. For this purpose, the theory of wavelets together with filter banks are used. The low and high pass filters are used for the decompositi...
متن کاملDecision criteria for Earthquake Early Warning applications
The recent large earthquakes have emphasized the importance of earthquake loss mitigation and how earthquake early warning (EEW) systems can help. An EEW system detects an earthquake initiation based on a seismic sensor network and broadcasts a warning of the predicted location and magnitude shortly before an earthquake hits a site. The typical range of this lead time is around tens of seconds ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 1988
ISSN: 0910-8025,2433-0000
DOI: 10.3130/aijsx.387.0_45