Lightning Protection Performance Assessment of Transmission Line Based on ATP model Automatic Generation
نویسندگان
چکیده
منابع مشابه
On the transmission line model for lightning return stroke representation
[1] The widely used transmission-line (TL) model of lightning return stroke in a vertical channel is most rigorously represented by a vertical phased array of current sources that produce a spherical transverse electromagnetic (TEM) wave in the case of return-stroke speed v equal to the speed of light c. If the radius of the lightning channel were equal to zero, the equivalent representation co...
متن کاملmortality forecasting based on lee-carter model
over the past decades a number of approaches have been applied for forecasting mortality. in 1992, a new method for long-run forecast of the level and age pattern of mortality was published by lee and carter. this method was welcomed by many authors so it was extended through a wider class of generalized, parametric and nonlinear model. this model represents one of the most influential recent d...
15 صفحه اولTime Domain Analysis of Graphene Nanoribbon Interconnects Based on Transmission Line Model
Time domain analysis of multilayer graphene nanoribbon (MLGNR) interconnects, based on transmission line modeling (TLM) using a six-order linear parametric expression, has been presented for the first time. We have studied the effects of interconnect geometry along with its contact resistance on its step response and Nyquist stability. It is shown that by increasing interconnects dimensions...
متن کاملDesigning Concept on Lightning Protection of Overhead Power Distribution Line
The principle is shown for lightning protection of power distribution lines taking the effects of surge arresters, overhead ground wires and their combined use into consideration. Moreover an outline of a rational design method targeting direct lightning hits, induced overvoltages and backflow currents from high structures.
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC Web of Conferences
سال: 2016
ISSN: 2261-236X
DOI: 10.1051/matecconf/20165503001